SpectrometerChromatographyIncubator/OvenCentrifugePhysical Property Test AutoclaveDeep Freezer/RefrigeratorFreeze DryerHomogenizerMedical EquipmentRotary EvaporatorElectrochemistry MeterWater PurificationKjeldahl Nitrogen ApparatusMicrowave DigestionLaboratory BalanceMicroscopeLab FurnitureElectrophoresis/Gel DocumentationLiquid HandlingLab Mixing EquipmentTemp-control EquipmentThermogravimetric Analyzer
< >

DW-GF Series Vertical Autoclave

Safety
1.Triple protection for lack of water
The bottom of the sterilization chamber is equipped with three different dry burning protection devices: liquid expansion type, copper temperature sensing type,and electric ion type(water level sensor),to avoid misjudgment caused by a single method.
2.Saturated steam monitoring
The system automatically monitors the purge out of cold air to ensure the pure steam environment.
3.Humanized design
The lid and bench corners are covered with insulation to avoid getting scald.
4.Auto trouble shooting
System will monitor the working status, and will cut the power, send out alarm, and report the error information once any abnormal situation detected.
5.Electrical protection
Prevention for over current,short ciucuit and electricity leakage.
6.Cooling LOCK open temperature
Each program can set different lid OPEN temperatures, especially for liquid program ,so as to prevent user from opening lid and causing burns when the articles are still in a high temperature state.
7.Evenly distributed interlock
Evenly distributed interlock device is safer and more reliable than ordinary interlocking devices.
8.Real time monitor
System will monitor the lid locking, pressure and temperature status on a real time basis to guarantee the safe and successful work of the autoclave.
9.Double protection for over pressure
Mechanical pressure gauge and electric sensing system,once pressure is abnormal, system will cut power, release the pressure and send out alarm.
10.Safety test function
Regular testing of system security and safety protection measures is possible.
11.Temperature monitor
Power cut and alaraming sent, if there is temperature is too high or themperature rising is abnormal.
12.One button to open
Press slightly to close, one button to open (if not safe inside, can not open).
Advanced
1.Touch screen
7-inch color LCD touch screen with Chinese /English choice , supporting glove wearing or pen touch sensing operation.
2.Data reading and curve conversion
Provide USB interface for easy reading or storage of sterilization data. The sterilization data is converted into curves for easy data analysis.
3.6 level of exhaust speed control (DA,DF,DR only)
After sterilization,you can choose different exhaust speed, and you can adjust it freely at any time of exhausting.
4.Auto drainage/Auto cleaning(option)
Added with a water pump, press the drainage button to start drainage, or set it to timed automatic drainage, Automatic cleaning can be set to regular cleaning or cleaning after each sterilization cycle.
5.5 level access permission
The operation permissions for instruments are divided into five levels, with each level of user having an independent password and multiple IDs that can be assigned. Each level of user has limited access to certain usage permiss1ons.
6.Sterilization record storage
Built in large capacity memory, can store 999 sterilization cycles and can be queried, printed or exported for easy traceability management.
7.F0 value caculation
F0 value is automatic caculated, can print out by micro-printer.
8.Air inlet filter(DR,DX only)
Filtration is higher than 99.99% in particlewith diameter of 0.2 um.
9.Biosafety function(DWS,DRS only)
Use a 0.2 μm PTFE filter packed in a housing to ensure that no biohazard aerosols, microorganisms and viruses are passing out through the filter during exhausting, so as to make sure the biology safety of the lab.
10.Drying(DR only)
Fully automatic drying: Equipped with an air pump and a 0.2um air filter, it automatically starts drying after sterilization. After sterilization, clean air will be put in to replace the wet air inside, so as to improve drying efficiency (Fully automatic drying is an option for DR only).
11.Dedorization(DX only)
A unique odor treatment system that can absorb odors and remove smell generated during the sterilization process, ensuring fresh laboratory air.
12.Monitor of exhaust filter(DWS,DRS only)
Exhaust filter is put inside a pressure resistant housing(stainless steel material) with an extra PT100 temperature sensor to monitor the temperature, so as to make sure the filter and housing are also being sterilized thoroughly,and will not.
13.Auto water fill(only for DF、DR models)
Equipped with automatic water feeding function, standard is with 28L water tank at the back to store water, option is direct water supply by pipe connection from water source while manufacturing.
14.Condenser(Option)
Equipped with a professional condenser, the steam generated during the sterilization process is converted into water through the condenser, achieving zero discharge of water vapor/mist.