SITE: HOME > PRODUCT

SpectrometerChromatographyIncubator/OvenCentrifugePhysical Property Test AutoclaveDeep Freezer/RefrigeratorFreeze DryerHomogenizerMedical EquipmentRotary EvaporatorElectrochemistry MeterWater PurificationKjeldahl Nitrogen ApparatusMicrowave DigestionLaboratory BalanceMicroscopeLab FurnitureElectrophoresis/Gel DocumentationLiquid HandlingLab Mixing EquipmentTemp-control EquipmentThermogravimetric Analyzer
< >

DW-GR Series Vertical Autoclave

Packing Size:
Gross Weight:
Packing Material:Paper Carton
Liquid/Battery/Motor:No
HS Code:8419200000

Advanced
Smart microcomputer control
“Inspiration”high speed microcomputer control,not only to monitor and control the whole process, but also to update the function in the future.
Program Memory storage system
User can set their own program, and saved in system.
Calibration interface
Offer temp.and pressure interface, together with the 3Q adapter joints, can insert max 15 sensors one time to do the calibration work
DAturated steam monitoring
The system automatically monitors the purge out of cold air to ensure the pure steam environmentk
Auto water fill(only for DF 、DR models)
Equipped with automatic water feeding function,standard is with 28L water tank at the back to store water, option is direct water supply by pipe connection from water source while manufacturing.
Biosafety function(only for DAS 、DFS 、DRS)
Use a 0.2 μm PTFE filter packed in a housing to ensure that no biohazard aerosols,microorganisms and viruses are passing out through the filter during exhausting, so as to make sure the biology DAfety of the lab.
Monitor of exhaust filter( only for DAS、DFS、DRS)
Exhaust filter is put inside a pressure resistant housing (stainless steel material) with an extra PT100 temperature sensor to monitor the temperature, so as to make
sure the filter and housing are also being sterilized thoroughly, and will not lead to secondary biohazard pollution.
SUS316L Stainless steel(Option)
Stronger corrosion, longer service life,and greater pressure resistance.
Humanized permission managemen
The management of the autoclave is classified into 3 levels,user-administrator- engineer, to make sure proper proper usage.
Agar program
Can heat up, melt, warm the agar or used as chamber preheating function
Waste program
Special waste program to sterilize the waste thoroughly
Auto start up appointment
Can make an appointment in 0- 15 days
Fully automatic drying( only for DR models)
Can set drying temp.and drying time. After sterilization, water will be drained out automatically, then an inbuilt pump will supply clean air into the chamber through an air filter.
Air filte( only for DR models)
Filtration is higher than 99.99% in particle with diameter of 0.2 μm.
LCD/USB/APP/Smart management system(Option)
LCD:5 inch LCD screen to show information in words
USB :to help to store and transfer the sterilization data
APP: Remote management APP(only in China)
Smart management system: linked with LIMIS/SCADA system(only in China)
Auto drainage(option)/Auto cleaning(only for DF/DR)
Added with a water pump, press the drainage button to start drainage, or set it to timed automatic drainage.
Condenser(Option)
Equipped with a professional condenser, the steam generated during the sterilization process is converted into water through the condenser, achieving zero discharge of water vapor/mist.
Safety Features
Humanized design:The lid and bench corners are covered with insulation to avoid getting scald.
Interlocking device:The exclusive patented "eight column evenly distributed" interlock device is safer and more reliable than ordinary interlocking devices.
Lid closing checking: Machine can not start if lid is not locking well by checking mechanically and electrically.
Real time monitor: System will monitor the lid locking, pressure and temperature status on a real time basis to guarantee the safe and successaul work of the autoclave.
Cooling lock OPEN temperature: Each program can set different lid OPEN temperatures,especially for liquid program ,so as to prevent user from opening lid and causing burns when the articles are still in a high temperature state
Triple protection for lack of water: The bottom of the sterilization chamber is equipped with three different dry burning protection devices: liquid expansion type, copper temperature sensing type, and electric ion type (water level sensor), to avoid misjudgment caused by a single method.
Double protection for over pressure: Mechanical pressure gauge and electric sensing system, once pressure is abnormal, system will cut power, release the pressure and send out alarm
Auto trouble shooting: System will monitor the working status, and will cut the power, send out alarm, and report the error information once any abnormal situation detected safety test function: Regular testing of system security and safety protection measures is possible.
Electrical protection: Equipped with a highly sensitive electrical protection system, effectively providing leakage protection, overcurrent and short-circuit protection.